Skip to content
Atlas Liaison Group

Bulk 62.5/125 multimode fiber

This multimode cable supplies 62.5-micron-core fiber in bulk for a planned termination.

Product photo of 3.0mm Bulk Plenum Zipcord Fiber Optic Cable, Duplex, multimode 62.5/125 OM1, YOFC Fiber, Orange, Spool, 1000 foot
3.0mm Bulk Plenum Zipcord Fiber Optic Cable, Duplex, multimode 62.5/125 OM1, YOFC Fiber, Orange, Spool, 1000 foot

Keeping a 62.5/125 multimode backbone consistent

A connector style alone cannot tell you whether the installed fiber is OM1. Two panels can both have SC couplers while the fibers behind them have different core sizes. Look for the cable legend, as-built drawing or original loss report.

Can an extension use a newer fiber on one section?

For an OM1 maintenance job, match the specified 62.5/125 cabling and jumpers. Ask the designer to review any change of core size. A mechanical fit can leave an optical mismatch that complicates both acceptance testing and later troubleshooting.

What will reach the enclosure?

Compare zipcord with multi-strand distribution and armored versions. Note entry hardware, cable diameter, fiber count and the preparation space inside the enclosure. Ask for matching pigtails by fiber type and connector when the design calls for splice termination.

What if part of the route is undocumented?

Look for a handoff at an intermediate panel or splice closure where the fiber may have changed. Have the fiber technician identify the path and record the evidence before ordering an extension. A legible label in the first closet identifies that segment but cannot describe an undocumented section farther along.

Identify the exact segment being repaired

An older multimode system can have several generations of fiber in neighboring enclosures. Trace the damaged segment on the installation drawing and check both end labels before selecting OM1 62.5/125 material. Compare the number of strands and the construction used along that segment. A fifty-foot patch at the rack is a different purchase from an unterminated distribution reel for repair work. Have the installer identify the intended splices or connectors, enclosure space and acceptance test. Preserve the updated route and fiber identifiers in the maintenance record after the repair is accepted. Retain a photo of the old jacket printing alongside the new cable reference.

An OM1 repair alongside a newer building network

Imagine the old access switch stays in service for one department while a newly renovated floor receives its own backbone. A contractor can encounter more than one generation of fiber in the same riser. For the repair, identify the two exact panel positions, obtain their earlier test record and match both core size and intended optics. For the renovated floor, have the project designer specify the new medium based on the planned network application. The two jobs may appropriately use different reels. Tag partial stock by project and fiber type at receiving. When the installation is complete, retain the route and strand identifiers even if an old switch is scheduled for retirement. Different equipment may later use that route, and its physical fiber history remains relevant to the next design review.

Compare parts for your setup

3.0mm Bulk Plenum Zipcord Fiber Optic Cable, Duplex, multimode 62.5/125 OM1, YOFC Fiber, Orange, Spool, 1000 foot

11E1-111NH

Configuration
Duplex
Fiber specification
multimode · 62.5/125 · OM1
Dimensions in listing
3.0mm
Length
1000 ft

Measure the physical route and slack at both ends before allocating a run from this 1000 ft supply.

Spiral Steel Armored 6 Strand Indoor/Outdoor Fiber Optic Distribution Cable, OM1 62.5/125 Multimode, YOFC Optical Fiber, Riser Rated, Black, Spool, 500 foot

20E3-206NF

Configuration
6 Strand
Fiber specification
OM1 · 62.5/125 · Multimode
Length
500 ft

Measure the physical route and slack at both ends before allocating a run from this 500 ft supply.

12 Fiber Indoor/Outdoor Fiber Optic Cable, Multimode 62.5/125 OM1, YOFC Fiber, Plenum, NFPA 262, Black, Spool, 1000ft

11E3-212NH

Configuration
12 Fiber
Fiber specification
Multimode · 62.5/125 · OM1
Length
1000 ft

Technical references

Products